Multimeters




Digital display
Liquid-Crystal Display
(LCD)
Multimeters are very useful test instruments. By operating a multi-position switch on the meter they can be quickly and easily set to be a voltmeter, an ammeter or an ohmmeter. They have several settings (called 'ranges') for each type of meter and the choice of AC or DC. Some multimeters have additional features such as transistor testing and ranges for measuring capacitance and frequency.


Choosing a multimeter

The photographs below show modestly priced multimeters which are suitable for general electronics use, you should be able to buy meters like these for less than £15. A digital multimeter is the best choice for your first multimeter, even the cheapest will be suitable for testing simple projects. If you are buying an analogue multimeter make sure it has a high sensitivity of 20kohm/V or greater on DC voltage ranges, anything less is not suitable for electronics. The sensitivity is normally marked in a corner of the scale, ignore the lower AC value (sensitivity on AC ranges is less important), the higher DC value is the critical one. Beware of cheap analogue multimeters sold for electrical work on cars because their sensitivity is likely to be too low.

Digital Multimeter, photograph © Rapid Electronics
Digital Multimeter

Digital multimeters

All digital meters contain a battery to power the display so they use virtually no power from the circuit under test. This means that on their DC voltage ranges they have a very high resistance (usually called input impedance) of 1Mohm or more, usually 10Mohm, and they are very unlikely to affect the circuit under test. Typical ranges for digital multimeters like the one illustrated:
(the values given are the maximum reading on each range)
  • DC Voltage: 200mV, 2000mV, 20V, 200V, 600V.
  • AC Voltage: 200V, 600V.
  • DC Current: 200µA, 2000µA, 20mA, 200mA, 10A*.
    *The 10A range is usually unfused and connected via a special socket.
  • AC Current: None. (You are unlikely to need to measure this).
  • Resistance: 200ohm, 2000ohm, 20kohm, 200kohm, 2000kohm, Diode Test.
Digital meters have a special diode test setting because their resistance ranges cannot be used to test diodes and other semiconductors.



Analogue Multimeter, photograph © Rapid Electronics
Analogue Multimeter

Analogue multimeters

Analogue meters take a little power from the circuit under test to operate their pointer. They must have a high sensitivity of at least 20kohm/V or they may upset the circuit under test and give an incorrect reading. See the section below on sensitivity for more details. Batteries inside the meter provide power for the resistance ranges, they will last several years but you should avoid leaving the meter set to a resistance range in case the leads touch accidentally and run the battery flat.
Typical ranges for analogue multimeters like the one illustrated:
(the voltage and current values given are the maximum reading on each range)
  • DC Voltage: 0.5V, 2.5V, 10V, 50V, 250V, 1000V.
  • AC Voltage: 10V, 50V, 250V, 1000V.
  • DC Current: 50µA, 2.5mA, 25mA, 250mA.
    A high current range is often missing from this type of meter.
  • AC Current: None. (You are unlikely to need to measure this).
  • Resistance: 20ohm, 200ohm, 2kohm, 20kohm, 200kohm.
    These resistance values are in the middle of the scale for each range.
It is a good idea to leave an analogue multimeter set to a DC voltage range such as 10V when not in use. It is less likely to be damaged by careless use on this range, and there is a good chance that it will be the range you need to use next anyway!

Sensitivity of an analogue multimeter

Multimeters must have a high sensitivity of at least 20kohm/V otherwise their resistance on DC voltage ranges may be too low to avoid upsetting the circuit under test and giving an incorrect reading. To obtain valid readings the meter resistance should be at least 10 times the circuit resistance (take this to be the highest resistor value near where the meter is connected). You can increase the meter resistance by selecting a higher voltage range, but this may give a reading which is too small to read accurately! On any DC voltage range:
    Analogue Meter Resistance = Sensitivity × Max. reading of range
e.g. a meter with 20kohm/V sensitivity on its 10V range has a resistance of 20kohm/V × 10V = 200kohm.
By contrast, digital multimeters have a constant resistance of at least 1Mohm (often 10Mohm) on all their DC voltage ranges. This is more than enough for almost all circuits.



Measuring voltage and current with a multimeter

  1. Select a range with a maximum greater than you expect the reading to be.
  2. Connect the meter, making sure the leads are the correct way round.
    Digital meters can be safely connected in reverse, but an analogue meter may be damaged.
  3. If the reading goes off the scale: immediately disconnect and select a higher range.
Multimeters are easily damaged by careless use so please take these precautions:
  • Always disconnect the multimeter before adjusting the range switch.
  • Always check the setting of the range switch before you connect to a circuit.
  • Never leave a multimeter set to a current range (except when actually taking a reading).
    The greatest risk of damage is on the current ranges because the meter has a low resistance.

Measuring voltage at a point

When testing circuits you often need to find the voltages at various points, for example the voltage at pin 2 of a 555 timer IC. This can seem confusing - where should you connect the second multimeter lead?
Measuring voltage at a point
Measuring voltage at a point.
  • Connect the black (negative -) lead to 0V, normally the negative terminal of the battery or power supply.
  • Connect the red (positive +) lead to the point you where you need to measure the voltage.
  • The black lead can be left permanently connected to 0V while you use the red lead as a probe to measure voltages at various points.
  • You may wish to fit a crocodile clip to the black lead of your multimeter to hold it in place while doing testing like this.
Voltage at a point really means the voltage difference between that point and 0V (zero volts) which is normally the negative terminal of the battery or power supply. Usually 0V will be labelled on the circuit diagram as a reminder.
Multimeter scales
Analogue Multimeter Scales
These can appear daunting at first but remember
that you only need to read one scale at a time!
The top scale is used when measuring resistance.

Reading analogue scales

Check the setting of the range switch and choose an appropriate scale. For some ranges you may need to multiply or divide by 10 or 100 as shown in the sample readings below. For AC voltage ranges use the red markings because the calibration of the scale is slightly different. Sample readings on the scales shown:
DC 10V range: 4.4V (read 0-10 scale directly)
DC 50V range: 22V (read 0-50 scale directly)
DC 25mA range: 11mA (read 0-250 and divide by 10)
AC 10V range: 4.45V (use the red scale, reading 0-10)
If you are not familiar with reading analogue scales generally you may wish to see the analogue display section on the general meters page.




Measuring resistance with a multimeter

To measure the resistance of a component it must not be connected in a circuit. If you try to measure resistance of components in a circuit you will obtain false readings (even if the supply is disconnected) and you may damage the multimeter. The techniques used for each type of meter are very different so they are treated separately:

Measuring resistance with a DIGITAL multimeter

  1. Set the meter to a resistance range greater than you expect the resistance to be.
    Notice that the meter display shows "off the scale" (usually blank except for a 1 on the left). Don't worry, this is not a fault, it is correct - the resistance of air is very high!
  2. Touch the meter probes together and check that the meter reads zero.
    If it doesn't read zero, turn the switch to 'Set Zero' if your meter has this and try again.
  3. Put the probes across the component.
    Avoid touching more than one contact at a time or your resistance will upset the reading!

Measuring resistance with an ANALOGUE multimeter

The resistance scale on an analogue meter is normally at the top, it is an unusual scale because it reads backwards and is not linear (evenly spaced). This is unfortunate, but it is due to the way the meter works.
  1. Set the meter to a suitable resistance range.
    Choose a range so that the resistance you expect will be near the middle of the scale. For example: with the scale shown below and an expected resistance of about 50kohm choose the × 1kohm range.
  2. Hold the meter probes together and adjust the control on the front of the meter which is usually labelled "0ohm ADJ" until the pointer reads zero (on the RIGHT remember!).
    If you can't adjust it to read zero, the battery inside the meter needs replacing.
  3. Put the probes across the component.
    Avoid touching more than one contact at a time or your resistance will upset the reading!
Multimeter scales
Analogue Multimeter Scales
The resistance scale is at the top, note that it reads
backwards and is not linear (evenly spaced).

Reading analogue resistance scales

For resistance use the upper scale, noting that it reads backwards and is not linear (evenly spaced). Check the setting of the range switch so that you know by how much to multiply the reading.
Sample readings on the scales shown:
× 10ohm range: 260ohm
× 1kohm range: 26kohm
If you are not familiar with reading analogue scales generally you may wish to see the analogue display section on the general meters page.